- Activate Master module.
- Select 8. Special, 3. Recalibrate.
- Select the controller to be recalibrated (e.g., Data Slider, Volume Slider, Left Wheel, Right Wheel, Pressure, Foot Pedal) and press ENTER.
- Hold the control at the minimum position and select/verify the minimum desired value, then press ENTER.
- Hold the control at the maximum position and select/verify the maximum desired value, then press ENTER.
- If recalibrating the Left Wheel, vary the wheel to select the center desired value, then press ENTER.
- Vary the control to check the range (should be 0 to 255), then press ENTER.
- Press Yes to save the calibration or No to cancel. The EIII will automatically advance to the next controller.
Source: Emulator III — emulatoriii-user-guide (manual)