- Activate Digital Processing module.
- Select 0 (Select Sample) to choose the sample.
- Select 3 (Truncation) to remove silence. Adjust Start/End points.
- Select 2 (Loop). Adjust Start and Length.
- Press ENTER and select Yes for Auto Correlate to smooth the loop.
Source: Emulator III XPs — e-mu-emulator-iiixp-operations-manual (manual)