← Repair Guides|Oscillator 2 Scale and Hi End Adjustments
Easy10 min

Oscillator 2 Scale and Hi End Adjustments

Symptoms this guide addresses

  • Oscillator 2 out of tune
  1. Set controls as per Osc 1 procedure except: Osc 1 Level (Min), Osc 2 Level (Max).
  2. Center trimpots R51 (Range 2), R48 (Scale 2), R72 (Hi-End).
  3. Monitor audio at J5.
  4. Depress and hold low A. Adjust R51 for 55Hz.
  5. Depress and hold high A. Adjust R48 for 220Hz.
  6. Repeat steps 4-5 until perfect two octave spread is obtained.
  7. Change Octave switch to 8'.
  8. Depress and hold low A. Adjust R51 for 220Hz.
  9. Depress and hold high A. Adjust R72 for 880Hz.
  10. Repeat steps 8-9 until perfect two octave spread is obtained.
  11. Repeat steps 4-10 as required.

Source: Rogue — moog-rogue-service-manual (manual)